This device stands between your plumbing and the public water supply. Its check valves have to seal tight, and a gauge test is the only proof that they still do.

Call now

or dial (365) 363-3352Visits booked around your hours

  • Test cocks connected to a calibrated differential gauge
  • Check valves and relief valves read and recorded
  • Failed assemblies rebuilt or replaced
  • Readings put on paper for you and for the City

A price before we startNothing cut or opened until you say yes.

  • Licensed & insureddetails confirmed on the call
  • Phones answered 24/7a person, not a queue
  • Price before we startcall-out rate on the phone
  • Old Toronto & East Yorkhouses, condos, businesses

What a backflow preventer does

When pressure in the city main drops, from a watermain break or a hydrant being opened, the flow can reverse and draw building water toward the street. A boiler loop, a carbonator, an irrigation line or a chemical feed could end up in the public supply. A backflow assembly uses spring-loaded check valves, and on higher-hazard sites a relief valve, to stop that.

  • Double check valve assembly (DCVA): two checks in series, used on moderate hazards.
  • Reduced pressure assembly (RP): two checks plus a relief port that dumps water if both leak.
  • Premise isolation: one assembly protecting the whole building at the water entry.
  • Zone or fixture protection: smaller devices on boilers, soda lines, hose bibs.

Signs it is time to call

  • Relief port on an RP assembly dripping or dumping
  • A test due date coming up on your last report
  • Low pressure after the assembly
  • A new boiler, soda system or irrigation line added

How a test is done

We close the downstream shut-off, attach a differential pressure gauge to the test cocks and read each check valve and the relief valve against the minimum values. A test takes the water off for a short time, so we book it when the building can cope.

When an assembly fails

  • Debris on a check seat: flushed and retested.
  • Worn rubber parts: rebuilt with the manufacturer’s kit.
  • Cracked body or seized shut-offs: replaced.

The City’s backflow program

Toronto’s water bylaw requires backflow prevention on many industrial, commercial, institutional and multi-residential properties, with testing on a set schedule and reports submitted to the City. The program gets updated, so confirm the current schedule with Toronto Water and file a copy of each report.

What’s included

What’s included

  • Shut-down booked with the building
  • Gauge test of each check and relief valve
  • Rebuild or replacement quote if it fails
  • Written results for your file

How the visit runs

  1. 1
    Locate

    Assembly, test cocks and shut-offs found and labelled.

  2. 2
    Test

    Differential gauge readings taken and recorded.

  3. 3
    Repair

    Rebuild kit or new assembly if a check fails.

  4. 4
    Report

    Results written up for your records.

Common questions

Will the building lose water for the test?

Briefly. We pick the time with you beforehand so nobody is mid-shift at a dry sink or a washroom that will not flush.

Do residential houses need backflow testing?

Ordinary single-family houses generally do not have a testable premise assembly. If you have an irrigation system or boiler, ask us what is fitted.

Keep the doors open. Call the plumber.

A plumber answers day and night, and the call-out rate is quoted before anyone drives over.

Call now · (365) 363-3352